This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | Last revision Both sides next revision | ||
wiki:design_construction [2022/02/02 17:31] henri.godfrin@neel.cnrs.fr |
wiki:design_construction [2022/02/03 14:02] henri.godfrin@neel.cnrs.fr |
||
---|---|---|---|
Line 49: | Line 49: | ||
* The still plays an important role: the **3He flow rate** of the dilution refrigerator, | * The still plays an important role: the **3He flow rate** of the dilution refrigerator, | ||
+ | |||
+ | ===== The Continuous heat exchanger | ||
+ | |||
+ | ===== The Step (" | ||
===== The Mixing Chamber | ===== The Mixing Chamber | ||
Line 73: | Line 77: | ||
- | ===== Troubleshooting ===== | + | ===== Troubleshooting |
* 1 K pot hot, pressure is low. Filling capillary blocked. Remove LHe so that the bath level is below the intake, keep 4He pressure in Pot above bath pressure. Having a heater on the 1K pot capillary can help, applying heat pulses... | * 1 K pot hot, pressure is low. Filling capillary blocked. Remove LHe so that the bath level is below the intake, keep 4He pressure in Pot above bath pressure. Having a heater on the 1K pot capillary can help, applying heat pulses... | ||